CONTACT FIRE OPERATION (CONTACT TRIP)
For contact fire operation, hold the Trigger and depress the Contact Arm against the work surface.
PROCEDURE
① Hold the Trigger.
② Depress the Contact Arm.
SINGLE FIRE OPERATION (ANTI-DOUBLE FIRE MECHANISM AND SEQUENTIAL TRIP)
For single fire operation, depress the Contact Arm against the work surface and pull the Trigger. Tool can not
fire a second nail until the Trigger is released and tool can cycle.
PROCEDURE
① Depress the Contact Arm.
② Pull the Trigger.
DRIVING DEPTH ADJUSTMENT DIAL
Deeper Shallow
Trigger Lock Dial
Adjustment Dial
ALWAYS disconnect air supply before adjustment dial.
① With air pressure set, drive nails into a representative material sample to determine if
adjustment is necessary.
② If adjustment is required, disconnect air supply.
③ Refer to the mark on the Adjust Spacer for direction to turn the adjustment dial.
④ Reconnect air supply.
Deeper
Shallow
TRIGGER LOCK MECHANISM
The tool is equipped with a Trigger Lock Mechanism. Push and rotate Trigger Lock Dial
from the LOCK to the UNLOCK position before driving nails.
Trigger